250V
[FA-] MPY, MPYC, MPYCY
Standards
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
Cable Construction
Conductor |
M |
Tinned annealed stranded copper, class 2 according to IEC 60228 |
Insulation |
P |
85°C EPR as per JIS C 3401 |
Cabling |
|
Insulated conductors shall be cabled. |
Bedding |
Y |
PVC as per JIS C 3401 |
Armor |
C |
Galvanized steel wire braid |
Sheath |
Y |
PVC as per JIS C 3401 |
Core identification |
|
Black No. on white insulation /Black No. on white insulation, G/Y |
Outer sheath color |
|
Black |
Cable Parameter
250V (FA-) MPY
No. of cores |
Conductor | Thick. of insulation |
Thick. of bedding |
(FA-) MPY | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
|||
mm² | No./mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
8.7 |
0.4 |
85 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
9.9 |
0.4 |
125 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
11.9 |
0.5 |
190 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
15.5 |
0.7 |
315 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
18.3 |
0.8 |
465 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
22.1 |
0.9 |
665 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
24.8 |
1 |
870 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
28 |
1.2 |
1160 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
35.9 |
1.5 |
1790 |
250V (FA-) MPYC
No. of cores |
Conductor | Thick. of insulation |
Thick. of bedding |
Dia. of steel wire |
(FA-) MPYC | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
10 |
0.4 |
155 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
11.2 |
0.4 |
205 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
0.3 |
13.2 |
0.5 |
290 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
0.3 |
16.8 |
0.7 |
445 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
0.3 |
19.6 |
0.8 |
615 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
0.3 |
23.4 |
0.9 |
840 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
0.3 |
26.1 |
1 |
1070 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
0.3 |
29.3 |
1.2 |
1290 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
0.4 |
37.7 |
1.5 |
2180 |
250V (FA-) MPYCY
No. of cores |
Conductor | Thick. of insulation |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCY | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
|||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
0.9 |
12 |
0.5 |
205 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
1.1 |
0.3 |
0.9 |
13.2 |
0.5 |
260 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
1.2 |
0.3 |
0.9 |
15.2 |
0.6 |
350 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
1.3 |
0.3 |
1 |
19 |
0.8 |
530 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
1.4 |
0.3 |
1.1 |
22 |
0.9 |
720 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
1.6 |
0.3 |
1.2 |
26 |
1 |
980 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
1.7 |
0.3 |
1.3 |
28.9 |
1.2 |
1240 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
1.8 |
0.3 |
1.3 |
32.1 |
1.3 |
1470 |
77 |
1 |
7/0.43 |
1.29 |
0.7 |
2.1 |
0.4 |
1.5 |
41.1 |
1.6 |
2470 |